Bogen PCMTIM User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
Note: PCMZPM modules with a label on the top marked "PCM2000 -B" are
high-power versions and can operate with 250W amplifiers. Such models
require Model PCMPS2 12V DC, 1.5A power supply to operate properly.
Relay Driver Output
Each zone module has three relay driver outputs: RD A, RD B, and RD C - one
for each speaker zone. When a zone is active, its relay driver is shorted to RD
COM through an open collector transistor. These drivers can be used to acti-
vate external relays to provide greater power capacity or to operate external
equipment. The power supply for these relays must be 12V DC or less. The total
sink current per driver cannot exceed 100 mA.
NOTE: Some power supplies are rated at 12V DC, but when lightly loaded are consid-
erably higher in output voltage. If the power supply for the relay has an unloaded out-
put of greater than 13V DC, the relay drivers may begin to conduct, energizing the
relay. If this problem occurs, you can either replace the supply with a regulated supply
or use a lower voltage supply.
PCMZPM